Our company provides maintenance, service and repair services for all kinds of applications as soon as possible with its technical staff with more than 20 years of experience and sufficient stock of spare exchanger plates and exchanger gaskets.
Plate heat exchanger service with professional criteria is basically carried out in five stages:


Stage 1


control phase

Dismantling the studs of the Plate Heat Exchanger and examining them in general terms. Marking of heat exchanger plates, determining the need for plate heat exchanger spare parts.

Stage 2

DeNOx-SCR system-Arasta
cleaning phase
Removing worn plate heat exchanger gaskets and cleaning the layers on the plate heat exchanger plates with the help of pressurized water and special chemical solvents.

Stage 3

DeNOx-SCR system-Arasta
Plate inspection
Visual inspection of Heat Exchanger Plates, determination of damage, replacement of deformed heat exchanger plates.

Stage 4

DeNOx-SCR system-Arasta
Dye Penetration, Leak Test
After visual inspection of the exchanger plates, Dye Penetration (Dye Leak Test) is performed on the suspected exchanger plates and the damaged exchanger plates are determined.

Stage 5

Plate Heat Exchanger Tightening
Gasket replacement phase
For plug-in plate heat exchanger gaskets, new plate heat exchanger gaskets are placed in the bearings on the heat exchanger plate, and for glued ones, they are glued onto the heat exchanger plate with adhesives suitable for the plate heat exchanger gasket material.